ELS-VN 100

ELS-VN 100

Fan unit with facia and overrun function V = 100 cbm/h

Ref.-No. 08138

Features

Fan unit “ultraSilence” with 100 m³/h air flow volume with built-in overrun timer, run on time 6, 15, 21 minutes adjustable, delayed start approx. 45 sec. (non-adjustable). Delivered complete with flat facia (white) and ultraSilence® technology. With permanent filter and dirt filter indicator as standard. Integrated quick plug connector for electrical connection. Insulation class II, protection to IP X5. For installation in zone 1 of bathrooms. Maintenance-free, energy saving ball bearing 230V/1 ph./50 Hz, 29 W. Sound power level 51 dB(A), sound pressure level 47 dB(A) with AL = 10 m² equivalent absorption surface in combination with casing type ELS-GU, discharge lateral. To DIN 18017, T.3, 2009-09, digit 7.2.4 footnote 5. Application: Simultaneous ventilation of bathroom and toilet (run on time mandatory to DIN).For ventilation of apartment kitchens. Technical data: Run on time: 6, 15, 21 minutes, Air flow volume in m³/h: 100, Power consumption in W: 29, Sound pressure level 1) in dB(A) with 10 m² equivalent absorption surface: 47 Sound power level 1) LWA in dB(A): 51. Electrical connection: 230V/1 ph./50 Hz. Electrical power supply in mm²: NYM-O 3x1,5 protection class II without PE, Wiring diagram: SS-876. All power and sound level statements to DIN 24163, DIN 24166, DIN 45635, DIN 44974. 1) in combination with casing type ELS-GU, discharge lateral.

Technical Data

General Information
Ref.-No.:08138
Type:ELS-VN 100
Flow rate free-blowing:107 m³/h
RPM:1790 min-1
Voltage:230 V , 1 ph , 50 Hz
Rated current (FLC) uncontrolled:0.17 A
Connect diameter:78 mm
Weight:1.85 kg
Wiring diagram no.:876